Bacterial Filtration Efficiency (BFE)
Bacterial Filtration Efficiency (BFE) is the efficiency of the medical face mask materials as a barrier to bacterial penetration. The test is required by ASTM F2100 (complies with ASTM F2101-19) and EN 14683:2019+AC.
The principle of the test is that a specimen of the mask material is clamped between a six-stage cascade impactor and an aerosol chamber. An aerosol of Staphylococcus aureus is introduced into the aerosol chamber and drawn through the mask material and the impactor under vacuum. The bacterial filtration efficiency (BFE) of the mask is given by the number of colony-forming units passing through the medical face mask material expressed as a percentage of the number of colony-forming units present in the challenge aerosol.
How SIG can help
SIG Laboratory can perform analysis of Bacterial Filtration Efficiency (BFE) of medical masks. We also ascertain whether the medical mask meets the criteria of ASTM F2100 (complies with ASTM F2101-19) and/or EN 14683:2019+AC.
Method of Analysis
SIG Laboratory performs analysis of Bacterial Filtration Efficiency (BFE) of medical masks by using a BFE tester.
Library of Knowledge
Mengenal Standar Lab Uji Makanan: Konsumen merasa lebih aman dengan adanya lab uji makanan
Standar Lab Uji Makanan adalah pedoman yang digunakan untuk menjamin prosedur pengujian pada sampel makanan secara aman, akurat dan dapat diandalkan. Pada umumnya, SIG Laboratory menggunakan standar ini untuk pengambilan sampel, pengolahan data, teknik analisis dan...
Produsen Makanan Butuh Lab Uji Makanan
Sebelum melakukan produksi di pasaran, produsen makanan wajib memenuhi syarat dan ketentuan yang diberikan Lab Uji Makanan seperti halnya SIG Laboratory. Mengapa? Karena hal ini menjadi ujung tombak tercapainya potensi bisnis di sektor pangan. Jadi, produsen makanan...
Fungsi Sheep Blood Agar dalam Mengidentifikasi Infeksi Bakteri
Sheep Blood Agar merupakan salah satu media pertumbuhan mikroorganisme yang memiliki peran penting untuk mengidentifikasi berbagai jenis bakteri. Salah satunya fungsi utama SBA yaitu memudahkan SIG Laboratory dalam meneliti adanya infeksi bakteri terhadap darah domba....
SIG Laboratory
Graha SIG, Jl Rasamala No. 20, Taman Yasmin, Bogor, Jawa Barat 16113.
Phone. +62 251 7532 348
WhatsApp. +62 82 111 516 516
Email. marketing@siglaboratory.co.id
SIG Jakarta
Jl. Percetakan Negara No. 52 B RT 006 / RW 001, Rawasari, Cempaka Putih, Jakarta Pusat 10570.
Phone. +62 21 2147 9292
SIG Medan
Jl. Bunga Asoka, Ruko Komp. Asoka Raya Residance No. 1, Medan Selayang, Sumatera Utara 20133,
WhatsApp. +62 822 7207 9665
Email. salesmedan.sig@saraswanti.com
SIG Semarang
Jl. Kanfer Raya Blok R No. 4 Pedalangan, Kec. Banyumanik, Kota Semarang, Jawa Tengah 50268.
Phone. +62 24 7004 0541
WhatsApp. +62 812 9000 5165
Email. cs.sigsmg@saraswanti.com
SIG Yogyakarta
WhatsApp. +62 896 4856 9422
Email. arifin.sig@saraswanti.com
Operational Hours
Monday to Friday
08.00 - 17.00 WIB.


FOLLOW US