Antimicrobial Test EN Method
Antimicrobial testing methods confirm the activity of antimicrobial agents under certain conditions. Antimicrobial products (disinfectants, antiseptics) can damage and inhibit the development of microorganisms and are necessary to test the safety, quality, efficacy. Several microorganisms include Pseudomonas aeruginosa, Escherichia coli, Staphylococcus aureus and Enterococcus hirae, and other bacterial strains upon request and tested according to BS EN and SNI EN standard methods.
How SIG Can Help
SIG laboratory provides a comprehensive range of antimicrobial testing for a range of products such as:
Method |
Application |
EN 1276:2019 |
Disinfectants |
EN 1276:2019 |
Antiseptics |
EN 1276:2019 |
Handwash |
EN 1276:2019 |
Floor cleaner |
EN 1276:2019 |
Perfuming clothes |
EN 1276:2019 |
Bleach |
Method |
Application |
EN 1650:2019 |
Disinfectants |
EN 1650:2019 |
Antiseptics |
EN 1650:2019 |
Handwash |
EN 1650:2019 |
Floor cleaner |
EN 1650:2019 |
Perfuming clothes |
EN 1650:2019 |
Bleach |
Method |
Application |
EN 1499:2013 |
Handwash |
EN 1500:2013 |
Handrub |
Method |
Application |
EN 13697:2015+A1:2019 |
Kitchen cleaner |
EN 13697:2015+A1:2019 |
Glass cleaner |
EN 13697:2015+A1:2019 |
Floor cleaner |
EN 13697:2015+A1:2019 |
Metal cleaner |
Method |
Application |
EN 13727:2012+A2:2015 |
Disinfectants for medical area |
EN 13727:2012+A2:2015 |
Antiseptics for medical area |
Method |
Application |
EN 13624 : 2013 |
Disinfectants for medical area |
EN 13624 : 2013 |
Antiseptics for medical area |
Therefore, SIG laboratory can support you in compliance with regulatory requirements and ensure your products are safe and high quality.
Several microorganisms can be tested according to the standard method of EN 1276: 2019:
● Bacillus cereus
● Bacillus sp
● Bacillus subtilis
● Enterobacter aerogenes
● Enterococcus faecalis
● Enterococcus hirae
● Escherichia coli
● Klebsiella pneumonia
● Listeria monocytogenes
● Pseudomonas aeruginosa
● Pseudomonas sp
● Salmonella sp
● Salmonella typhimurium
● Shigella sonnei
● Shigella sp
● Staphylococcus aureus
● Staphylococcus epidermidis
● Streptococcus sp.
● Vibrio cholerae
Several microorganisms can be tested according to the standard method of EN 1650:2019:
● Aspergillus niger
● Aspergillus brasiliensis
● Candida albicans
Several microorganisms can be tested according to the standard method of EN 1499:2013 & EN 1500:2013
● Escherichia coli K12
Several microorganisms can be tested according to the standard method of EN 13697:2015+A1:2019
● Bacillus subtilis
● Enterobacter aerogenes
● Enterococcus faecalis
● Escherichia Coli
● Klebsiella pneumonia
● Listeria monocytogenes
● Pseudomonas aeruginosa
● Salmonella sp
● Salmonella typhimurium
● Staphylococcus aureus
● Aspergillus niger
● Candida albicans
Several microorganisms can be tested according to the standard method of EN 13727:2012+A2:2015
● Bacillus cereus
● Bacillus sp
● Bacillus subtilis
● Enterobacter aerogenes
● Enterococcus faecalis
● Enterococcus hirae
● Escherichia coli
● Klebsiella pneumonia
● Listeria monocytogenes
● Pseudomonas aeruginosa
● Pseudomonas sp
● Salmonella sp
● Salmonella typhimurium
● Shigella sonnei
● Shigella sp
● Staphylococcus aureus
● Staphylococcus epidermidis
● Streptococcus sp.
● Vibrio cholerae
Several microorganisms can be tested according to the standard method of EN 13624 : 2013 :
● Aspergillus niger
● Aspergillus brasiliensis
● Candida albicans
Method of Analysis
We offer these tests in line with standard test methods, including:
● EN 1276:2019
● EN 1650:2019
● EN 1499:2013
● EN 1500:2013
● EN 13697:2015
● SNI EN 13727 : 2012
● SNI EN 13624 : 2013
Biocidal activity test of chemical disinfectants and antiseptics according to European Standards (EN), based on reducing the number of test microorganisms under specified conditions. The EN method’s scope is testing of active substances of disinfectants/antiseptics and end products that are ready to be applied on hands and the environment.
Library of Knowledge
Remote Audit of GMP+ International for Registered Laboratory
GMP+ International audit activities for registered laboratory has been successfully performed. Thus, SIG's big ambition in actualizing a better place to live #towardsasaferworld becomes even more real. This activity aims for SIG to support the testing needs of...
Detection of Primary Aromatic Amines As Aniline
It is known that food coloring is an additive commonly used to improve the appearance of food or drinks, but during the manufacturing process there is an azo coupling reaction which has the potential to produce residues of aromatic amine compounds such as aniline and...
Kunjungan Industri Universitas Pendidikan Indonesia
Rabu 18 Agustus 2021 Suatu kehormatan bagi SIG dapat menjadi tamu pada kegiatan Kunjungan Industri (KI) Online Universitas Pendidikan Indonesia (UPI) Bandung.Kegiatan industrial visit ini merupakan sebuah kegiatan observasi langsung yang diharapkan dapat menjadi wadah...
SIG Laboratory
Graha SIG, Jl Rasamala No. 20, Taman Yasmin, Bogor, Jawa Barat 16113.
Phone. +62 251 7532 348
WhatsApp. +62 82 111 516 516
Email. marketing-sig@saraswanti.com
SIG Jakarta
Jl. Percetakan Negara No. 52 B RT 006 / RW 001, Rawasari, Cempaka Putih, Jakarta Pusat 10570.
Phone. +62 21 2147 9292
SIG Surabaya
AMG Tower, 12th Floor, Jl. Dukuh Menanggal 1-A, Gayungan, Surabaya, Jawa Timur, 60234.
Phone. +62 31 8253 1288
WhatsApp. +62 818 885 165
Email. marketing@sigsurabaya.com
SIG Semarang
Jl. Kanfer Raya Blok R No. 4 Pedalangan, Kec. Banyumanik, Kota Semarang, Jawa Tengah 50268.
Phone. +62 24 7004 0541
WhatsApp. +62 812 9000 5165
Email. cs.sigsmg@saraswanti.com
SIG Medan
Jl. Bunga Asoka, Ruko Komp. Asoka Raya Residance No. 1, Medan Selayang, Sumatera Utara 20133,
WhatsApp. +62 822 7207 9665
Email. salesmedan.sig@saraswanti.com
SIG Yogyakarta
WhatsApp. +62 896 4856 9422
Email. arifin.sig@saraswanti.com
Operational Hours
Monday to Friday
08.00 - 17.00 WIB.
FOLLOW US